Perform The Appliance Search; Preparation; Bluetooth Communication; Set Up The Bluetooth Connection - Truma iNet Box Mode D'emploi

Masquer les pouces Voir aussi pour iNet Box:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Perform the appliance search

Preparation:

1. Connect all suitable TIN-bus-capable Truma appliances to
the Truma iNet Box and to the Truma CP plus control panel.
2. Switch on the power supply for all connected appliances
3. Perform the appliance search depending on the Truma iNet
Box interfaces used.
Appliance search, TIN1 interface:
All appliances are automatically recognised.
The iNet-capable appliances connected to the Truma CP plus
control panel must be known to the Truma CP plus control
panel. If this is not the case, you must perform the following
steps on the Truma CP plus:
Start the search of the appliances under menu item
"Service menu" -> "RESET" -> "PR SET".
After confirmation, the Truma CP plus control panel initialises
itself. "INIT .." appears on the display while this is in progress.
This stores in the Truma CP plus control panel the appliances
that have been found.
Appliance search, TIN2 interface:
Press the button (Figure 2 – 1) for at least 20 seconds.
A short flashing of the blue LED indicates – appliances saved
and reset done.
Resetting to the factory settings deletes all the data.
Following a repair / retrofit, the appliance search must
be repeated on the Truma iNet Box or with the Truma CP plus
control panel.

Bluetooth communication

Set up the Bluetooth connection

To connect the mobile terminal device to the Truma iNet Box,
the mobile terminal device must be switched on and Blue-
tooth must be activated (see the operating instructions of the
mobile terminal device).
– Start the Truma App and open the remote control
– Press the button (Figure 2 – 1) for approximately 1 second.
If the Bluetooth pairing is active, the Truma iNet Box becomes
visible for up to 2 minutes in the mobile terminal device and
the blue LED flashes at the same time (Figure 1). The name
" Truma iNet Box" appears on the mobile terminal device.
The Bluetooth connection to the mobile terminal device can
be made.
Confirm the " Truma iNet Box" connection in the Bluetooth
settings of your mobile terminal device.
Up to 20 mobile terminal devices (mobile phones, tab-
let PCs) can be logged in on the Bluetooth connection.
Four mobile terminal devices can control the Truma iNet Box
simultaneously.
The first mobile terminal device set up (administrator) remains
permanently in the Truma iNet Box memory. If the maximum
number of mobile terminal devices has been reached, the
21st mobile terminal device overwrites the 2nd one in the
memory and so on.
The first mobile terminal device set up (administrator)
can only be deleted by restoring to the factory setting
(see "Factory setting" on page 22) in the Truma iNet Box.
17

Publicité

Table des Matières
loading