Troubleshooting Guide - Truma iNet Box Mode D'emploi

Masquer les pouces Voir aussi pour iNet Box:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting guide

If you encounter problems with the Truma App and / or the Truma iNet Box, we recommend checking that the app is up to date,
and performing an update if necessary.
In this eventuality we also recommend a firmware update for the Truma iNet Box in accordance with the instructions in the firm-
ware update section.
Truma iNet
Truma iNet Box is not ready for oper-
Box and
ation
system
(green LED is not on)
My connected appliances cannot be
controlled
GSM
Poor network reception
No operation possible
(red LED is on)
I have sent a command via SMS but my
appliance has not yet received it
I do not receive SMS confirmation
20
Fault
– Check all plug connections and whether the power supply is
– Check that the Truma iNet Box is ready for operation
– Check that the appliances are connected correctly and ready for
– Perform a restart of the Truma iNet Box. To do this, disconnect
– Check the installation of the Truma iNet Box
– Check that the network covers your current location
– Check the internal / external GSM antenna changeover switch
– Check that the used Mini-SIM card is functioning properly (e.g.
– Check the PIN in the set-up assistant of the Truma App
– Check the internal / external GSM antenna changeover switch
– Check the phone number in the set-up assistant of the Truma App
– There may be a delay in the SMS being forwarded due to the
– Check that the used Mini-SIM card is functioning properly and
Remedy
sufficient
operation
the power supply for about 10 seconds. (*)
SIM card has been blocked by the operator)
mobile phone provider or poor network cover
has credit

Publicité

Table des Matières
loading

Table des Matières