WARNING
handling and disposing of cleaning, disinfection, or sterilization solutions.
WARNING
Reuse, reprocessing, or resterilization may create a risk of contamination of the device.
WARNING
WARNING
cause serious injury to the operator or damage to the instrument and will void the warranty.
Contact Verathon
®
WARNING
can contact the patient and can exceed 41°C (106°F) as part of normal operation. Patient
contact with this area of the blade during intubation is unlikely, as it would cause an
obstruction of the camera view. Do not maintain continuous contact with this area of the
blade for longer than 1 minute; it is possible to cause thermal damage such as a burn to the
mucosal tissue.
WARNING
are not compatible with this system:
• 0574‑0176 (Spectrum™ LoPro S3)
• 0574‑0177 (Spectrum LoPro S4)
Refer to part numbers when assessing whether a blade is compatible with the system. For
more information about compatible components and accessories, see page 5.
WARNING
or body fluids capable of transmitting pathogens, all cleaning facilities must be in compliance
with (U.S.) OSHA Standard 29  CFR  1910.1030 "Bloodborne Pathogens" or an equivalent
standard. For more information, visit www.osha.gov.
WARNING
and has no sign of damage. Do not use this product if the device appears damaged. Ensure
that alternative airway management methods and equipment are available.
WARNING
placing it in the charging cradle.
WARNING
GlideScope Go monitor.
SYMBOLS
For a full list of caution, warning, and informational symbols used on this and other Verathon
products, please refer to the Verathon Symbol Directory at verathon.com/symbols.
Ensure that you follow the manufacturer's instructions for
Do not reuse, reprocess, or resterilize single‑use components.
No modification of this equipment is allowed.
Do not attempt to open the system components. This may
Customer Care for all servicing needs.
The area surrounding the camera in the video laryngoscope
GlideScope blades labeled with the following part numbers
Because the product may be contaminated with human blood
Before every use, ensure the instrument is operating correctly
Ensure the monitor is clean and free of contamination before
The charging cradle should be used only for charging the
• 0574‑0178 (Spectrum MAC S3)
• 0574‑0179 (Spectrum MAC S4)