Figure 26b Hidden Weights: selecting p1 weight
position.
Press
at any time to exit the "Hidden
Weights" programme.
4. To make work easier mark the position of the
unbalance Pe on the tyre. To do this, move the
wheel to a centred position and make a chalk
mark at 6 o'clock if the "LAS" configuration is
active and at 12 o'clock if the "H12" or "CLP"
configuration is active.
5 Turn the wheel to the position in which you wish
to apply the first outer weight (P1) and press
to confirm.
To select the exact position of the weight P1
relative to the Pe unbalance, use 6 o'clock as
a reference if the "LAS" configuration is active,
or 12 o'clock if the "H12" or "CLP" configuration
is active.
The angle between P1 and Pe must be less than
120°.
6 If the angle selected is greater than 120°, the
machine displays the message shown in Fig.
26a for approximately 3 seconds to indicate
that another position must be chosen. If the
angle selected is less than 120°, the machine
displays the message shown in Fig. 26c, allowing
the user to continue to the next step.
Figure 26c Hidden Weights: selecting position P2
7 Turn the wheel to the position in which you
wish to apply the second outer weight (P2) and
EM 9550 - Operator's manual
press
To select the exact position of the weight P2
relative to the Pe unbalance, use 6 o'clock as
a reference if the "LAS" configuration is active,
or 12 o'clock if the "H12" or "CLP" configuration
26b
is active.
The angle between P1 and P2 must be less than
120° and must include the outer weight Pe.
8 If the angle selected is greater than 120°, the
machine displays Fig. 26d for approx. 3 seconds
to indicate that the procedure in step 7 must
be repeated correctly. If instead the selected
angle is less than 120°, the machine will im-
mediately show the value of weight P2 on the
display. The
is displayed on the LCD display in the active
function area.
Figure 26d Hidden Weights: Incorrect P2 weight
position.
9 Manually turn the wheel or press
with the guard raised, the two unbalance values
calculated are displayed in alternation on the
outer side display as the angular position of
the wheel changes.
10 Apply each of the two balancing weights
as described in the chapter "ALU1P, ALU2P
programmes".
11 Once the Hidden Weights programme proce-
dure is complete, you may continue working
with any other programme.
The HIDDEN WEIGHT function is combined with
the MOBILE PLANES function to allow balancing
weights which are multiples of 5 grams to be
26c
used.
to confirm.
HIDDEN WEIGHT icon