Several spins must be performed to balance
the wheel
It was jolted during the spin.
- Repeat the spin, avoiding any undue stress during the
acquisition.
It does not firmly rest on the floor.
- Check that the rest is stable.
The wheel is not locked correctly.
- Tighten the fixing ring nut well.
The machine has not been calibrated correctly.
- Carry out the calibration procedure for the sensor.
The entered geometric data are not correct.
- Check that the data inserted correspond to the dimensions
of the wheel and, if necessary, correct them.
- Carry out the external sensor calibration procedure (width).
WARNING
The "Spare parts" handbook does not authorise
the user to carry out work on the machine with
the exception of those operations explicitly de-
scribed in the User Manual. It only enables the
user to provide the technical assistance service
with precise information, to minimise delays.
MAINTENANCE
WARNING
The manufacturer declines all responsibility for
claims deriving from the use of non original spare
parts or accessories.
WARNING
Unplug the machine from the power supply
and make sure that all moving parts have been
locked before performing any adjustment or
maintenance operation.
Do not remove or modify any part of the machine
(except for service interventions).
CAUTION
Keep the work area clean.
Never use compressed air and/or jets of water
to remove dirt or residues from the machine.
Take all possible measures to prevent dust from
building up or raising during cleaning operations.
EM 9550 - Operator's manual
Keep the wheel balancer shaft, the securing ring
nut, the centring cones and flange clean. These
components can be cleaned using a brush previ-
ously dripped in environmentally friendly solvents.
Handle cones and flanges carefully so as to avoid
accidental dropping and subsequent damage that
would affect centring accuracy.
After use, store cones and flanges in a place where
they are suitably protected from dust and dirt.
If necessary, use ethyl alcohol to clean the display
panel.
Perform the calibration procedure at least once
every six months.
INFORMATION REGARDING
MACHINE DEMOLITION
If the machine is to be scrapped, remove all electri-
cal, electronic, plastic and metal parts
and dispose of them separately in accordance with
current provisions as prescribed by law.
ENVIRONMENTAL
INFORMATION
The following disposal procedure shall be exclu-
sively applied to the machines having the crossed-
out bin symbol on their data plate
This product may contain substances that can be
hazardous to the environment and to human health
if it is not disposed of properly.
The following information is therefore provided
to prevent the release of these substances and to
improve the use of natural resources.
Electrical and electronic equipment must never be
disposed of in the usual municipal waste but must
be separately collected for their proper treatment.
The crossed-out bin symbol, placed on the product
and on this page, reminds the user that the product
must be disposed of properly at the end of its life.
In this way it is possible to prevent that a non
specific treatment of the substances contained in
these products, or their improper use, or improper
use of their parts may be hazardous to the environ-
ment or to human health. Furthermore, this helps
to recover, recycle and reuse many of the materials
contained in these products.
.
UK
73