20.1.5 PERIODIC CHECKS TO BE CARRIED OUT
It is necessary to check periodically that the electric cables and the electric parts are undamaged.
21. NON ROUTINE MAINTENANCE AND REPAIRS
Non routine maintenance and repairs must be carried out by qualified personnel authorised by the manufacturer. The manu-
facturer declines any responsibility for jobs carried out by unauthorised personnel or the use of non-original spare parts.
22. TROUBLESHOOTING
The following table shows the most frequent problems, possible causes and remedies.
PROBLEM DESCRIPTION
The appliance does not come on
The refrigerator unit does not start
The refrigerator is continuously working but
does not reach the set temperature
Refrigerator does not stop at set temperature
Ice blocks on evaporator
Pool of water or ice in drip tray
Appliance is noisy
IN ORDER TO GUARANTEE THE EFFICIENCY OF THE APPLIANCE AND ITS CORRECT FUNCTIONING THE MANUFAC-
TURER'S INTRUCTIONS MUST BE FOLLOWED AND PERIODIC SERVICING MUST BE CARRIED OUT BY PROFESSIONALY
QUALIFIED PERSONNEL.
(LEGAL REQUIREMENT FOR THE PREVENTION OF ACCIDIENTS AT WORK AND THE INSTALLATION OF ELECTRICAL AP-
PLIANCES)
IT IS OBLIGATORY TO BE IN ACCORDANCE WITH POWER SUPPLY REGULATIONS.
23. SPARE PARTS
23.1 SUPPLY OF ORIGINAL SPARE PARTS
For the substitution of any parts, spares can be obtained at our authorized centres, on giving
•. Serial.number.and.year.of.manufacture.(see.plaque.A)
•. Component.identification.number
Any malfunctioning due to non-original spare parts will not be recognised by our technicians.
POSSIBLE CAUSE
The main switch is "off"
There is no tension
Other
Set temperature is reached
Defrosting is in operation
Control panel is broken
Other
Room is too hot
Condenser is dirty
Refrigerator fluid is insufficient
Condenser fan has stopped
Door not properly closed
Evaporator is frosted up
Defrost valve is open
Control panel is broken
Temperature probe is broken
Door is nor airtight
Improper use
Control panel is broken
Blocked
Appliance not levelled
Appliance not levelled
Contact with external bodies
Screws or nuts loose
Other
18
SOLUTION
Main switch "on"
Check plug, socket, fuse, electric connection
Contact technical assistance
Set new temperature
Wait foe end of cycle, switch off and switch back on
Contact technical assistance
Contact technical assistance
Air better
Clean condenser
Contact technical assistance
Contact technical assistance
Check door seals
Manual defrosting
Contact technical assistance
Contact technical assistance
Contact technical assistance
Close door
Contact technical assistance
Contact technical assistance
Clean drain and discharge
Contact technical assistance
Check that appliance is level
Check that no tube or ventilator fan is in contact with
external bodies
Tighten
Contact technical assistance