EQUIPMENT DATE AND TIME SETTING :
• SET Press and hold on a second
• Ù and Ú by pressing the "RTC" labeled point value
• Press SET button and pull your hand. ''YY''is seen on the screen, use arrow keys enter last 2 digits of year
• Press SET button and pull your hand. ''mm'' is seen on the screen, use arrow keys enter month with 2 digits
• Press SET button and pull your hand. ''dd'' is seen on the screen, use arrow keys enter day with 2 digits.
• Press SET button and pull your hand. ''hh'' is seen on the screen, use arrow keys enter clock with 2 digits by 24 hour system.
• Press SET button and pull your hand. ''nn'' is seen on the screen, use arrow keys enter minutes with 2 digits.
•
without touching any buttons for 60 seconds waiting for the system to return to normal operation.
ALARMS
EXPLANATION
AL
Low temperature alarm;
Check the room temperature. Check the values of the parameters A1 and A2.
AH
High temperature alarm;
Please contact an authorized service.
PR1
Cabin sensor error
Please contact an authorized service.
PR2
Evaporator sensor error
Please contact an authorized service
PR3
Cabin sensor error
Please contact an authorized service.
Rtc
Real time clock and date on error. re-adjust according to previous setting date and time.
Id
Door switch alarm. Close door. If the alarm continues, contact with your service.
PF
Indicates that there is a power outage alarm. Device warns of electricity is interrupted for a certain time
Not: To return to normal working, pressing any button on the device.
COH
Condenser sensor reaches the sensed temperature indicates that the first alarm.
Please clean the condenser.
Not: The compressor will continue to work and If the temperature drops the alarm off