Télécharger Imprimer la page

Virtus VN8 Mode D'emploi page 165

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
IMPORTANT WARNINGS
Frenox control panels have different features to store the products safely in the refrigerator, and also it has some special
features to identify the problems easily.
PRODUCT OPENING: Press to POWER button. Product will start to work and compressor and fan icon will light up on the
screen. Press POWER button to turn off product. Product will turn off.
***IMPORTANT NOTICE: Closing of your product only from the control panel allows you to switch to stand-by mode. Pull
the plug from the socket to disconnect all electrical power to the control panel. When you cut the power to the control panel,
it will detect a power outageve and then when you rerun it will give an alarm related to power outages
TO SET THE TEMPERATURE: Press the set button continiously. The "C" icon will start blinking, and you will see the SET
temperature of the product. Use the up and down buttons to set the temperature that you desire, press the SET button. The
temperature SET Value will start blinking and then it will stop. Now you can use the product in the new setting temperature.
The product will work with + 3 C° difference
TO ENTER PARAMETER LIST: SET and DOWN button press for 5 seconds continiously. HY will disappear on the screen. Find
the parameter listing that you would lşke to change by the UP or DOWN button, after making the necassry change on the
parameter, press the SET button, to confirm the parameter. To enter the second row of parameters, after you see the HY on
the screen, press the SET and Down arrow continiously untill tou see the PR2 on the screen.
H.A.C.C.P FEATURE: According to HACCP regulation, parameters providing high and low temperature alarm in the control
panel of FRENOX. 10 alarm status can be recorded. There are two types of alarm status. ( HA or LA)
* press UP button to enter LOG ALARM menu.
* Recording alarms will be shown. AL0 oldest record, AL9 is the last record. If you do not have a recorded alarm 'AL'
will be shown
* press SET button to examine the details of the alarm .
Example: started on 09 May 2011 07.41 am and finished 09may2011 09.04 am an alarm condition will be displayed
in the following way. 'HA' , 'h07' , 'n41' , 'Y11' , 'M05' , 'd03' , '09h' , '04n' , '11Y' , '05M' , '03d'
* press and hold for 5 seconds to delete all alarm records DEFROST button and then wait appear LOG ALARM menu.
INTERNET CONNECTION: if need, you can put in internet connecting card to control panel by adding specific information
transofmeryou can check your product on the internet , Your arousal is possible in case of alarm. These features agree with
our dealer where you purchased the product.
H.A.C.C.P FRENOX CONTROL PANEL DIXELL XW60K
7

Publicité

loading

Ce manuel est également adapté pour:

Vl8Vn8-gVl8-gVn7-mVl7-mVn7-mg ... Afficher tout