Télécharger Imprimer la page

Virtus VN8 Mode D'emploi page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
9.2 FAILURE
The following errors, you can fix yourself by checking the possible causes.
The device does not work, check lamp does not light up:
•. Check.mains.plug.is.properly.plugged.into.the.power.outlet.
•. Check.whether.the.socket.fuse.intact.
Too much noise, do the following checks
•. T he.appliance.should.stand.firm.on.the.ground
•. Cold.circuit.current.in.the.prevention.of.noise-other.note.of.it.
The temperature is not low enough, you perform the following checks
•. Adjustment.."Set.Temperature".value.in.accordance.with.section.set?
•. Excessive.amounts.of.fresh.food.have.been.placed.on.24-hour.watch.the.gauge.
•. Established.as.a.separate.thermometer.shows.me.the.correct.value?
•. Outward.flow.of.air.eligible?
•. T he.installation.location.is.too.close.to.a.heat.source?
If none of the above causes mentioned, if you cannot resolve the fault yourself, please contact your nearest customer service.
Please type in the tag type of device, the device number. Devices on the label located on the upper side wall of the cabinet.
10. CONNECTION AND INSTALLATION
10.1 INSTALLATION
•. Stay.away.from.exposed.to.direct.sunlight,.over.oven,.heating.and.like.installation.places.
•. T he.installation.site.must.be.flat.and.level.ground.
•. Keep.a.sufficient.distance.from.the.wall.for.opening.and.closing.the.cover.hassle.of.device.
•. Do.not.close.the.space.between.bottom.freezer.and.ground..It.is.important.for.the.compressor.to.provide.cooling.air.
10.2 CONNECTION
•. Current.type.at.the.installation.site.(alternative.current).and.voltage,.should.be.the.same.as.stated.on.the.label.Progress..
Model label in the core, on the left, is located next to vegetable eyes. Wall plug should be protected by a fuse or 10 A,
must be in an easily accessible place.
11. VERTICAL TYPE REFRIGERATOR
MODEL
VN4
CAPACITY (LT)
DIMENSIONS
(Wx L x H)
INTERIOR VOLUME (M³)
COOLING
-2/8
DEGREE.(C°)
COOLINF
FUNCTION
REFRIGERANT
R 134
COMPRESSOR POWER
1./.5
ELECTRICAL POWER
308
(W)
POWER SUPPLU
220V-240V.AC.NPE.-./50Hz
(V/Hz)
LIQUID PROTECTION
WEIGHT (KG)
75
TECHNICAL SPECIFICATIONS OF VERTICAL TYPE REFRIGERATOR (1)
400LT
VL4
VF4
VN7-BN7
400
60 x 60 x 190
70 x 78 x 205
0,45
-10/-25
-0/-5
-2/+8
FANLI
STATİK
R 404 A
R 404 A
R 134 A
1./.2
1./.2
1./.3
338
387
335
220.V-240V.AC.NPE-/50Hz
1./IP.20
80
85
120
700 LT
1400 LT
VL7-BL7
VN14-BN14
700
1400
140 x 78 x 205
0,71
-10/-25
-2/+8
FANLI
FANLI
R 404 A
R 134 A
1./.2
1./.3
510
440
220V.-240V.AC.NPE-/50Hz
1./.IP.20
1./.IP.20
125
175
13
VL14-BN14
VN21/A
210 x 78 x 205
1,42
-10/-25
-10/-25
-2/+8
R 404 A
R 134 A
1
1./.3
755
474-415
220V.-240V.AC.NPE-/50Hz
180
295
2100 LT
VN21/B
VN21/C
2100
2,13
-10/-25
-10/-25
-2/+8
-2/+8
-0/-5
FANLI
R 404 A
R 134 A
1./.2
1./.3
474-474-
474-755
755
1./.IP.20
305
335

Publicité

loading

Ce manuel est également adapté pour:

Vl8Vn8-gVl8-gVn7-mVl7-mVn7-mg ... Afficher tout