16. MANUFACTURER COMPANY INFORMATION
17. AUTORIZED SERVICES INFORMATION
18. ACTIVATION
18.1 PREPARATION BEFORE ACTIVATION
•. Make.sure.the.cables.and.electric.power.that.connecting.to.product.provide.the.necessary.electrical.power.
•. Make.sure.Counter.type.and.Vertical.type.refrigerator.is.placed.away.from.heat.sources..Such.as.furnaces,.radiators,.direct.
sunlight.
•. Leave.space.at.least.75.mm.(3.inch).at.the.back.of.the.refrigerator..This.is.important.for.condensation.
•. Cooling.unit.should.be.away.from.strong.air.flow.obstructions,.should.be.a.place.where.comfortable.and.breathable...
•. W ith.the.upper.body.of.refrigerator.and.attic.must.be.min.50.cm.(9.inch).space.
Should.be.maximum.ambient.temperature.of.+43.°.C.(+109.°.F).for.products.in.order.to.work.correctly..It.can.be.highest.
ambient.temperature.+32.°.C.(+95.°.F).where.using.static.cooling.system.products.
Failure to comply with the above conditions, operating performance of the product will be serious decline, prema-
ture wear of the compressor and also consumes more energy than usual.
18.2 CONNECTION
Please follow the instructions listed below before running Frenoks Endüstriyel Soğutma Sanayi ve Ticaret A.Ş products.
18.3 ELECTRICAL
Making.horizontal.and.vertical.electrical.connections.is.under.user's.responsibility..Check.that.the.electrical.connections.
according to the rules of electrical connection the country.
•. Check.even.voltage.be.sure.that.the.same.written.on.the.label.
•. Check.electrical.outlet.that.according.to.electrical.power.rules.
•. Check.whether.Exposed.cable.
•. Check.the.grounding.
USE OF DEVICE IS DANGEROUS AND ILLEGAL WITHOUT GROUNDING.
If you are connected multiple products to the same source, there should be a separate electrical outlet each other.
18.4 DRAINAGE CONNECTION
If you do not have evaporator in your product, it must be connected for the water drainage hose for removal of water out.
19. OPERATION
19.1 PERSONAL
The staff who are to use and installed the appliance, must possess (or acquire trough adequate formation and training) the
following skills and must understand the contents of this manual and all the relevant Safety Information:
•. General.technical.knowledge.enough.to.understand.the.contents.of.the.Manual.
•. Awareness.of.the.main.hygiene,.accident.prevention.and.technological.regulations.
19.2 PUTTING INTO OPERATIONS
If the equipment has been mistakenly positioned horizontally during transport, wait about 2 hours, after putting it into a
vertical position, before it into operation.
16