5.4.4
Segment display, green and orange LED, fuse
Fig. 20
*RUN* flashes when the microprocessor is working.
*S1* lights up when one of the pump's buttons is pressed.
*P* lights up, the pump should now work and the pump's
protection should be on.
*P* flashes, the pump should be turned on in time mode and the
pump's protection should be on.
Error message
*FV* lights up if the voltage in the microprocessor overloads.
Green and orange LEDs on the circuit board
green LED lights up: Power supply present in the circuit board
[Volt].
orange LED lights up: Motor protection has triggered (over
current).
Check the motor protection settings.
Circuit board fuse
Replaceable fuse: 3.15 A T
The fuse only needs replacing if the green LED [V] is not lit up.