5.3.3
Installing the pump and connecting it to the pipework
1.
Fasten the pump horizontally on a vibration-absorbing base.
NOTICE
The pump can be damaged by unauthorised mechanical strains
being placed on the pump!
Take the pipe up directly before the pump and connect it free
of tension.
2.
Connect the pipe free of tension according to the VDMA
standard sheet 24277. Use compensators if necessary.
3.
Ensure that any leaks cannot cause consequential damage.
Install a suitable retainer if necessary.
4.
There must be ground drainage
Calculate the size of the ground drain according to the
following criteria:
– Size of the swimming pool
– Circulation flow rate
5.4
Electrical connection (Qualified specialist)
WARNING
Risk of electric shock due to incorrect connections!
Electrical connections must always be carried out by
authorised specialists.
Observe VDE and utility company regulations.
Install pumps for swimming pools and their protection
according to DIN VDE 0100-702.
Install a disconnecting device with at least a 3 mm contact
gap per pole to interrupt the power supply.
WARNING
Risk of electric shock due to voltage on the housing!
A built-in or external overload switch which is set correctly
must be installed for pumps with three-phase or A.C. motors
without motor protection. In doing so, observe the values on
the motor name plate.
Protect power supply with a ground fault circuit interrupter,
nominal residual current I
Only use suitable pipe types according to regional
regulations.
06|2020
≤ 30 mA.
FN
Installation
EN 31