Télécharger Imprimer la page

RIB SUPER 6000 Mode D'emploi page 29

Operateur irreversible por portails coulissantes
Masquer les pouces Voir aussi pour SUPER 6000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A - CONNEXIONs
IT Is COMPULsOrY TO
sET THE DIP 13 Of THE
CONTrOL PANEL IN THE
ON POsITION.
T1
T2
JA
T T R
S
T
N
3-PHASE LINE
400V + N
L1 - N
230Vac 50/60Hz POWER SUPPLY (TO BE DONE BY THE
J1
MANUFACTURER)
BLINKER (40 W MAX.)
U
CONNECTION TO T1 AND T2 POWER RELAYS
J2
V-W
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
J3
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN
CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN
OPENING
STOP
STOP CONTACT (NC)
J4
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command
and safety inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
AERIAL
RADIO ANTENNA
J5
COM
COMMON CONTACT (common line for all the command
and safety inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
PROBE
IS NOT AVAILABLE
J6
s3
J5
Tr1
Tr2
J4
J3
sW s1
J2
U
V
W
J1
MOTOR
3 P
PTO
J7
J6
sW1
sW2
sW3
ENCODER
IS NOT AVAILABLE
J7
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
J8
PROG.
PROGRAMMING BUTTON
s3
LOW SPEED
IS NOT AVAILABLE
Tr1
IS NOT AVAILABLE
Tr2
TORQUE
SW S1
DO NOT rEMOVE THE JUMPEr!
sW s1
OTHErWIsE THE OPErATOr WILL NOT WOrK!
DIP-SWITCHES
sW1
sW2
sW3
POWER RELAYS FOR THE COMMAND OF THE MOTOR
T1 - T2
TT
MOTOR THERMAL CONTACT
JA
R-S-T
THREE-PHASE POWER SUPPLY
N
NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
29
29
29
29
I
NNEr THErMAL OVErLOAD
CUT-OUT sWITCHEs (per CEI
2-3/IEC 34-1)
The electrical protections on the
SUPER 6000 motor power line may
not be sufficient to protect against
overloads. If the cooling conditions
J8
worsen, the motor overheats but the
electrical conditions do not change,
which
inhibits
line
Installing
bimetallic
PTO on the s1/r4
control panel solves
this problem.
This is a normally-
closed electromechanical device that
opens when the threshold temperature
is reached; it automatically resets
when the temperature falls below the
threshold level.
T
G
B
protections.
the
device
T

Publicité

loading

Ce manuel est également adapté pour:

Aa38004