6. Operating conditions
Maximum flow rate [gpm]
Maximum pressure [psi]
Maximum system pressure [psi]
Maximum suction lift [ft]; see page 62
Minimum ambient temperature [°F]/[°C]
Maximum ambient temperature [°F]/[°C]
Minimum liquid temperature [°F]/[°C]
Maximum liquid temperature [°F]/[°C]
Net weight [lbs]
Sound pressure level [dB(A)]
Tank volume [oz]
Air pressure in tank [psi]
Connections
Priming and drain plugs
6.1 Suction lift
The maximum suction lift of the pump can be
determined from the diagram, page 62.
Example:
If the suction lift is 10 ft, the length of the suc-
tion pipe must not exceed 72 ft.
MQ 3-35
22
51
108
25
32/0
113/45
32/0
95/35
29
< 70
13.5
22 to 25
1" NPT
3/8" GAS
MQ 3-45
65
7