3.5.1 – ecognition o t e door o en and closed ositions
The control unit must be made to recognize the opening and closing posi-
tions of the door. In this phase, the door stroke from the closing mechani-
cal stop to the opening mechanical stop is detected.
In addition to position, the STOP input configuration is detected and
memorised in this phase as well as the existence or non-existence of the
PHOTO input "Phototest".
1 Make sure the carriage is engaged.
2 On the control unit, press the P3 button [A] for at least three seconds,
then release the button (Fig. 47).
47
B
• Wait for the control unit to complete the recognition stage: closing,
opening and closing again of the door.
• If during the recognition phase any device trips or P3 is pressed, the
cycle is immediately interrupted. You then have to start again from the
beginning.
• During the recognition procedure, the courtesy lamp flashes like the
flasher itself.
3 If the P2 and P3 LEDs [B] flash at the conclusion of the recognition
process, it means that an error has occurred; see section 5.5 ("Trouble-
shooting").
4 Press button T1 on the ECCO5... transmitter to open the door. Then
press it again to close it. During these cycles the controller memorises the
force required at each point of the door's travel.
Do not interrupt these two cycles.
If this occurs, the recognition process described in point 1 must be
repeated.
The recognition stage of the positions can be repeated again at any time,
even after the installation (for example, if one of the mechanical stops is
moved); just repeat the procedure starting from step 1.
IMPORTANT: During the position search process, if the belt is
not sufficiently tensioned, it may slip on the pinion. If this happens,
interrupt the process by pressing button P3 and tension the belt by
screwing in nut [F]. Now repeat the process from step 1.
48
3.5.2 –
ec ing t e radio transmitter
To check the transmitter, simply press any of its 4 buttons and check that
the red LED flashes and the automation does the commanded action.
The command assigned to each button depends on how it was memo-
rised (see par. 5.4 "Memorising radio transmitters"). The supplied trans-
mitter is already memorised and its buttons have the following functions:
14 – English
49
A
Keys
T1
T2
T3
T4
T5
3.6 - ADJUSTMENTS
3.6.1 – etting t e door s eed
The door opens and closes at two speeds: "slow" or "fast".
To go from one speed to the other, press button P2 [B] briefly; LED P2 [A]
turns on or off to indicate fast and slow respectively.
50
3.6.2
The door opens and closes in two ways:
• single cycle (semi-automatic): the first command opens the door; it
stays open until the next command closes it.
F
• full cycle (automatic close): the first command opens the door; it closes
automatically after a short time (see par. 5.1.1 "Setting parameters with
the radio transmitter").
To go from one mode to the other, press button P3 [B] briefly; LED P3 [A]
turns on or off to indicate full and single cycle respectively.
51
T1
T3
Paired command
Step-by-Step (SbS)
Partial open
Open only
Close only
Auxiliary function: not present
A
-
etting t e o erating mode
A
[A] Led
T5
T2
T4
[B]
B
B