10 Open the door manually to the desired open position, then place the
rear mechanical stop [R] near the carriage (Figure 34) and secure it by
tightening the scre firmly [Q].
3.3.4 –
otocells o tional
Caution: disconnect the power supply to the system before performing
any installation operations.
• position each photocell 40/60 cm above the ground • position
them on the opposite sides of the zone to be protected • position
them as close as possible to the door (maximum distance
• a tube for passing the cables must be present in the fastening
point • orient the TX transmitter towards the central zone of the
RX receiver (allo ed misalignment: maximum 5°)
01. Remove the front glass (Phase 01 - Fig. 35)
02. Remove the upper casing then the internal casing of the photocell
(Phase 02 - Fig. 35)
03. Perforate the lower casing in the point where the cables should pass
(Phase 03 - Fig. 35)
35
01.
04.
10 – English
P
15 cm)
02.
05.
Ø < 5 mm
34
R
Q
11 Make sure that the release cord can be activated at a height less than
1.8 m.
04. - Position the lower casing in the point where the tube for the pas-
sage of the cables arrives and mark the perforation points (Phase
04 - Fig. 35)
- Use a percussion drill to drill the wall with a 5 mm bit. Insert the 5
mm wall plugs (Phase 04 - Fig. 35)
- Pass the electrical cables through the relevant holes and fasten the
lower casing with the screws (Phase 04 - Fig. 35)
05. - Connect the electric cable to the relative terminals on the TX and RX
units (Fig. 35-5). Make the electrical connections based on the func-
tion required and to the Fig. 42.
- Put back in place, in the following order, the inner casing followed by
the upper casing to be fastened with the two screws then, lastly, insert
the cover and exert slight pressure to close it (Phase 05 - Fig. 35).