5.6.3 – ontrol unit
On the control unit there is a set of LEDs, each of which can give special
indications both during normal operation and in case of malfunctions.
LED OK [A]
Off
On
One flash every second
2 long flashes
Series of flashes separated
by a pause
LED STOP [B]
Off
On
One flash every second
LED P1 [C]
Off
On
Series of flashes, from 1 to 4
LED P2 [D]
Off
On
1 flash every second
2 flashes every second
LED P3 [E]
Off
On
1 flash every second
2 flashes every second
20 – English
Status
Malfunction
Serious malfunction
All OK
The status of the inputs has changed
It corresponds to the flashing light or the courtesy signal (see table 12).
Status
STOP input activation
All OK
No device recognised or malfunction of
recognised devices
Status
All OK
Mode 1 memorisation
Mode 2 memorisation
Status
All OK
All OK
The recognition process has not been run
or the data in memory is incorrect
Device recognition process under way
Status
All OK
All OK
The recognition process has not been run
or the data in memory is incorrect
Position recognition process under way
61
A
TABLE 13
Action
Make sure there is power supply; check to see if the fuses are
blown; if necessary, identify the reason for the failure and then
replace the fuses ones of the same type.
There is a serious malfunction; try switching off the control unit
for a few seconds; if the condition persists, it means there is a
malfunction and the circuit board has to be replaced.
Normal operation of control unit.
This is normal when there is a change in one of the inputs: SbS,
STOP, triggering of photocells or the radio transmitter is used.
Action
Check the devices connected to the STOP input.
STOP Input active.
Some equipment may be faulty; check and repeat the recognition
process (see par. 3.5.1 "Recognition of the door open and closed
positions").
Action
No memorisation under way
Normal during Mode 1 memorisation which lasts at most 10s
Normal during Mode 2 memorisation which lasts at most 10s
Action
Select speed "slow"
Select speed "fast"
Run position recognition again (see par. 3.5.1. "Recognition of
the door open and closed positions").
Indicates that the controller is searching for connected devices
(lasts a few seconds).
Action
Cycle operation
Full cycle operation
Run position recognition again (see par. 3.5.1. "Recognition of
the door open and closed positions").