HPT 300 • HPT 300C
NOTE
a) Connecting to an air duct results in the loss of some air-flow and heat pump
capacity in the system.
b) If the air outlet of the main unit is connected to a canvas air duct, condensate
drops may generate outside this canvas air duct during the operation of the
main unit. Please, ensure the drainage of condensate water. In this case, it is
recommended to mount the heat insulation layer outside the air duct outlet.
Installation of the HPT300(C) hot water tank in a closed space.
It is forbidden to use the HPT300(C) hot water tank outdoors or in a place exposed to
rain or moisture.
If the HPT300(C) hot water tank is connected to an air duct with outdoor termination,
reliable waterproof protection needs to be ensured for the air duct, to prevent
rainwater from entering the appliance.
88
Figure 9.1.-5.
Weather
proofing
Figure 9.1.-6.