HPT 300 • HPT 300C
WARNING
Due to potential danger, please keep packaging materials (clips, plastic sacks,
polystyrene foam etc.) away from children.
During handling or transportation of the appliance after its first start up, please,
observe the warnings about the maximum tilting angle above and ensure that all water
has been discharged from the tank. If you do not have the original packaging any
more, please, provide protection to the appliance and its parts similar to the original
packaging.
2. TECHNOLOGICAL CHARACTERISTICS
2.1. Construction features
The HPT300(C) heat pump boiler is basically composed of an upper part (Figure 2.1.-1.)
containing the heat pump unit and a lower part (Figure 2.1.-2.) containing the storage
tank. The storage tank of sanitary hot water – having a volume of (300 l) – is covered
by an enamel coating internally and by a highly efficient thick polyurethane insulation
layer externally, where the latter is covered by the metal surface of the appliance.
The pipe radiator, limiter, anode indicator electronic unit and magnesium indicator
anode are located inside the heater. The condensate water discharge pipe branch is
located in the rear part of the above circular tray. The control panel with a display is
located in the front part. All the other parts of the heat pump circuit are located above
the storage tank in a precisely designed order that enables optimal operation, and
reduced vibration and noise emission.
Figure 2.1.-1
58