HPT 300 • HPT 300C
The
symbol indicates that the controlled power function has been enabled.
When the
symbol flashes, low tariff controlled power is currently available to the
appliance.
Reset button
You can delete an error code appearing on the appliance by simultaneously pressing
the buttons
and
.
If you press the buttons
and
simultaneously during program run, you can
delete the values set for the program.
To increase the service life of the appliance, a short-circuit monitoring mechanism
is installed in your heat pump. As a result, the compressor of the appliance may
sometimes start up with a short delay after the start of the heat pump. When this self-
defence mechanism activates, the small symbol shown in the picture flashes until the
compressor also starts up.
Anti-Legionella function
The anti-legionella function is designed to lower the risk of bacterial infection in the
tank, when it is not used for an extended period of time. After the installation and
start-up of the HPT300 appliance, the control system continuously monitors the water
temperature in it. The anti-Legionella function is accessible in all active modes. When
the appliance detects that the water temperature has not changed for a long time
in it (i.e. there is no water withdrawal), the control system automatically activates this
function, and heats the water above 60 °C.
The anti-Legionella function can be disabled in the Installation menu.
78