d) The selected location must be ready to host the discharge opening for condensate
water connected to the upper part of the appliance with corrugated pipe.
e) Please, make sure that the location of operation, and the electric and hydraulic
systems to be connected to the appliance fully comply with all relevant regulations.
f) The selected location must be equipped (or must be suitable for being equipped)
with a single phase 230 V ~ 50 Hz external mains switch.
g) According to the definitions of the relevant regulations, the selected location has
to comply with IP protection class (ingress protection rating) of the appliance.
h) Do not expose the appliance to direct sunlight through any window even.
i) The appliance may not be exposed to effects of especially aggressive agents, such
as acidic vapours, environment saturated with dust or gases.
j) The appliance may not be directly connected to a mains supply network without
overvoltage protection.
k) The appliance must be placed and operated as close to the withdrawal locations
as possible, in order to limit the diffusion of heat along the pipeline.
l) Proper electrical, water and sewage network (floor sink) connections must be
ensured at the installation location.
m) To decrease heat loss attributable to the hot water pipe, the appliance should
be installed the closest possible to the hot water withdrawal locations. In case of
longer distances, the hot water pipe should be added heat insulation.