Note: The brute force limitation is defaulted to initial shipment state values when the drive is completely reset,
or self-destruct feature is activated, or brute forced. If Admin changes the User PIN, or a new User PIN is set when activating
the recovery feature, the User PIN brute force counter is zeroed (0) but the brute force limitation is not affected. If Admin
changes the Recovery PIN, the Recovery PIN brute force counter is zeroed.
Successful authorisation of a certain PIN will zero the brute force counter for that particular PIN, but not affect the other PINs
brute force counter. Failed authorisation of a certain PIN will increase the brute force counter for that particular PIN, but not
affect the other PINs brute force counter.
33. How to set the User PIN Brute Force Limitation
Note: The User PIN brute force limitation setting is defaulted to 10 consecutive incorrect PIN entries when
32. How to set the User PIN Brute Force Limitation
the drive is either completely reset, brute forced or the self-destruct PIN is activated.
The brute force limitation for datAshur PRO
attempts from 1 to 10 consecutive incorrect PIN entries.
To configure the User PIN brute force limitation, first enter the "Admin Mode" as described in section 5. Once the drive is in Admin
Mode (solid
BLUE
LED) proceed with the following steps.
1. In Admin mode, press and hold down both
7 + 0 buttons
2. Enter the number of attempts for the brute force limitation (between 01-10), for example enter:
• 01 for 1 attempt
• 10 for 10 attempts
3. Press the SHIFT (
) button once
Note:
When the datAshur PRO
time the drive can accept instructions via the keypad allowing it to be configured with a host of security features. If no key event
happens within 30 seconds, the datAshur PRO
RED
LED which then fades out to the Idle state (all LEDs off).
To immediately exit Admin Mode (solid
LED switches to a solid
RED
must first be in the idle state (all LEDs off) before an Admin/User PIN can be entered.
User PIN can be reprogrammed and set by the administrator. This feature can be set to allow
2
is in Admin Mode, the
BLUE
2
will exit Admin mode automatically - the solid
2
BLUE
LED), press and hold down the SHIFT (
LED which then fades out to the Idle state. To access the drive contents (data), the datAshur PRO
www.istorage-uk.com
Solid
BLUE
LEDs blinking together
Blinking
GREEN
solid
GREEN
BLUE
LED indicating the brute force limitation was
successfully configured
LED will remain on and solid for 30 seconds only, during which
) button for a second - the solid
LED will change to
GREEN
and
and
BLUE
LEDs will switch to a
LED for a second and then to a solid
BLUE
LED switches to a solid
BLUE
BLUE
2