4 CONFIGURATION
4.4.2 Unit
ENTER
UNIT
K-FACTOR
Note: Return to the main menu is only available from the «TOTAL» Sub-Menu.
4.4.3 K-factor
The K-factor of the fitting is entered within this menu (see instruction manual fitting S030).
The "TEACH IN" function allows the practical determination of the specific K-factor. The
user only needs to run a known volume through his system.
Example: In order to determine a volume as accurately as possible, the user shall fill a tank
of 100 l. When the message "TEACH YES" appears, he presses the ENTER key to start the
measuring procedure. The message "FILL END" (end of filling) will appear. He then switches
on a pump or opens a valve. As soon as the tank is empty, he switches off the pump or
closes the valve. Pressing Enter stops the measurement. The user will then be asked to
enter the volume (100 l). The calculated K-factor is displayed after confimation.
ENTER
BATCH
0......9
TOTAL
ENTER
ENTER
E-20-
BATCH CONTROLLER SE35
ENTER
m LITER
LITER
M3
US GAL
IMP GAL
ENTER
LITER
M3
US GAL
IMP GAL
LIT/SEC
LIT/MIN
LIT/H
M3/MIN
M3/H
UGAL/SEC
UGAL/MIN
UGAL/H
IGAL/SEC
IGAL/MIN
IGAL/H