Choice Of Type Of Arc Ignition (P Sector); Hf High-Frequency Ignition - Cebora 553 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 135
5.2

Choice of type of arc ignition (P sector)

High frequency (HF) ignition, the arc ignites by high frequency/voltage discharge.
Contact ignition, touch the workpiece with the electrode tip, press the welding torch trigger and raise
the electrode tip.
EVO LIFT Touch the workpiece with the electrode tip, press the welding torch trigger and raise the
electrode tip; as soon as the electrode is raised, a high frequency/voltage discharge is generated which
lights the arc. Particularly suitable for precision spot welding.
EVO START After the frequency/voltage discharge, which lights the arc, the parameters are set that
favour joining of the edges of the material to be welded during the fi rst stage of welding. The duration
of the parameters mentioned above may be adjusted from the main screen by selecting parameter EVO
ST. (see section 5.2.4)
After lighting the contact arc, the parameters are set that favour joining of the edges of the material to
be welded during the fi rst stage of welding. The duration of the parameters mentioned above may be
adjusted from the main screen by selecting parameter EVO ST. (see section 5.2.4)
Touch the workpiece with the electrode tip, press the welding torch trigger and raise the electrode tip.
As soon as the electrode is raised, a high frequency/voltage discharge is generated which lights the
arc. Parameters are also set that favour joining of the edges of the material to be welded during the
fi rst stage of welding.
The duration of the parameters mentioned above may be adjusted from the main screen by selecting
parameter EVO ST (see section 5.2.4).
5.2.1

HF High-frequency ignition.

The arc is ignited by means of a high frequency/voltage discharge, the discharge stops as soon as welding current
begins to circulate or after a timeout (3s). This type of ignition does not require the workpiece to be touched with
the electrode tip. Unlike contact ignition, with HF ignition, there is no risk of contaminating the workpiece with the
tungsten electrode. Always try to ignite the arc at a maximum distance of 2-3 mm from the workpiece.
60/89
Select and confi rm P sector for arc ignition.
Select and confi rm type of ignition. N.B. the box for the process in
use is highlighted in green.
3301230/A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

558555557

Table des Matières