Type/Model
Supply voltage:
(Primary)
Installation dimensions
Lift
Weight min./max. without drive
motor
Protection category
Protection category without drive
motor
Max. lifting speed
Current consumption
Continuous sound pressure level
Duty cycle
(at room temperature / 20 °C)
Power consumption
Ambient temperature
Load
Max. torque
Max. acceleration "a"
Repeatability
Lead angle accuracy
Service life
Technical information in the
material number
LZ 70 PL/Tr Spindle 20x4
depending on the type of motor
When the drive motor is adapted, IP 54 protection category is achieved.
When the drive motor is adapted using the RK seal set, IP 65 protection
24 mm/s
depending on the type of motor
depending on the type of motor
TQ1 _ A2A1D34AA _ _ _ _
1 = IP54
3 = IP65
Stroke length
4 = Spindle Tr20x4
6. Product Information
LZ 70 PL/Tr Spindle 20x8
see table 1
5 mm - 1,000 mm
2.5 kg to 9.5 kg
category is achieved.
no IP protection
65 dB (A)
30 % duty cycle
(Max. 50 % duty cycle)
+ 0 °C to + +50 °C
Diagram 3
20 Nm
2
3 m/s
± 0.2 mm
± 0,15 mm/300 mm lift
3,000 h
TQ1 _ A2A1D37AA _ _ _ _
2 = IP54
4 = IP65
7 = Spindle Tr20x8
48 mm/s
Stroke length
45