6. Product Information
6.2 Technical specifications LZ 70 electric cylinder
Type/Model
Supply voltage:
(Primary)
Installation dimensions
Lift
Weight min./max. without drive
motor
Protection category
Protection category without drive
motor
Max. lifting speed
Current consumption
Continuous sound pressure level
Duty cycle
Power consumption
Ambient temperature
Load
Max. torque
Max. acceleration "a"
Repeatability
Lead angle accuracy
Service life
Technical information in the
material number
44
LZ 70 PL/KG Spindle 20x10
depending on the type of motor
When the drive motor is adapted, IP 54 protection category is achieved.
When the drive motor is adapted using the RK seal set, IP 65 protection
500 mm/s
depending on the type of motor
Diagram 1
depending on the type of motor
Diagram 1
TQ1 _ A2A1D35AA_ _ _ _
1 = IP54
3 = IP65
Stroke length
5 = Spindle KG20x10
LZ 70 FL/KG Spindle 20x20
see table 1
5 mm - 1,000 mm
3 kg to 10 kg
category is achieved.
no IP protection
75 dB (A)
+ 0 °C to + 60 °C
15 Nm
2
10 m/s
± 0.05 mm
T7 (± 53 m/300 mm lift)
10,000 h
TQ1 _ A2A1D36AA_ _ _ _
2 = IP54
4 = IP65
6 = Spindle KG20x20
1000 mm/s
Diagram 2
Diagram 2
Stroke length