Connecting Can Bus (Control Current) Cables; Technical Data - Vetus BOW PRO A Serie Manuel D'installation

Masquer les pouces Voir aussi pour BOW PRO A Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Bow thruster
The configuration as supplied is for application as a bow thruster.
Stern thruster
Configure a stern thruster by cutting through the red wire as indica-
ted in the drawing.
• Reinstall the cover and tighten the glands.
Main power fuse 2
In the connection unit, there
is a main power fuse on the
controller.
This fuse protects the con-
troller and motor against
short
circuit/overloading
and it must remain present
under all circumstances.
When replacing the fuse, the replacement must be of the
same rating.
5.6

Connecting CAN bus (control current) cables

See diagrams from page
97
if multiple panels have to be connected.
The CAN bus power supply must always be connected to
12 Volt (≥10 V, ≤16 V). Use the E-Drive MPE1KB key switch as
power supply.
As required by international standards, all neutral (negative)
conductors of the DC system must be connected to one central
point. This prevents not only dangerous situations and corrosion
problems, but also error messages in the CAN bus system.
22
020802.05
Red
n
ote
n
ote
c
aution
6

Technical data

Type
:
Electromotor
Type
:
For DC systems
:
Current (In)
:
Power consumption :
Rating
:
Protection
:
Insulation class
:
Motor controller
MCV
:
Transmission
Gears
:
Gear ratio
:
Lubrication
: oilbath, outboard gear oil SAE80W or EP 90
:
Propeller
No. of blades
:
Profile
:
Material
:
Rated thrust
:
Control circuit
Fuse
:
Thrust-tunnel
Steel model
dimensions
: O.D. outside 121 mm, wall thickness 4,5 mm
blasted, coated with: SikaCor Steel Protect.
treatment
:
Suitable for all kinds of protection systems.
Plastic model
dimensions
:
material
:
Aluminium model
dimensions
:
material
:
Weight
Excl. thrust-tunnel
:
[1]
S2 't' min.  Activation time 't' min. continuously or a max. of 't'
min. per hour at maximum power.
vetus® Installation manual BOW PRO Series Thrusters: BOWA0301 and BOWA0304
BOWA0301
BOWA0304
EC Motor (8VAC-1.2kW)
12 V =
48 V =
174 A @ 12,0 V
45 A @ 48,0 V
199 A @ 10,5 V
50 A @ 42V
2,1 kW
S2 - 10 min.
[1]
IP44
F
MCV30024
MCV25048C
+ MVC0301S
+ MCV0304S
Bevel gear helical teeth
1,39 : 1
ca. 0.024 litre (0.8 fl.oz.)
6
asymmetrical
polyacetal (Delrin ®)
300 N (30 kgf, 66 lbf )
Blade type fuse 'ATO' 5 A
I.D. inside 110 mm, wall thickness 5 mm
glass fibre reinforced polyester
I.D. inside 110 mm, wall thickness 5 mm
aluminium, 6060 or 6062 (AlMg1SiCu)
24 kg (53 lbs)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bow pro bowa0301Bow pro bowa0304