2.5.5 Cable and connector for resolver connexion
resolver Cable
6 x 0,24mm
+ 1 shielding per pair
Typical characteristics:
Reference
Colour
Test voltage
Outside diameter
Dynamic radius of curvature
Alternating bending strength (R = 75 mm)
Oil resistance
External sheath
The connector plugs and resolver cables are described in the appendix 2.
2.6 Using restriction
If the nominal torque is hold in the stopped position or at very low speed (< 10 rpm), the torque should
be limited to 80% of Io (permanent current at low speed) to avoid an excessive overheating of the
motor. The front flange should normally dissipate a part of the losses of the motor. The size of the end-
plate should be at least 400 mm square and 12mm thickness.
The resolver cable must be separated from the power cable.
Cables fitted with connectors may be provided by us : ask for
details.
The cable is made up of 6 wires twisted and shielded in pair.
The shielding must be earthed on the servoamplifier side only
The recommended cable can use resolver signals from up to 50 m
away. For greater distances ask for details.
Servoamplifier connection: comply with the relevant servoamplifier
installation instructions.
2
PVD 3535D – 01/2014
:
:
:
:
:
:
:
:
19
6537 P0001
red, black markings
1 500 V
7,1 ± 0,2 mm
≥ 75 mm
≥ 5 million cycles
Very good
Polyurethane