Ball Valve with Integral Pressure Relief
EBV(T)-PR Series
INSTALLATION AND SERVICING INSTRUCTIONS
SD-421 / 42021
Standard Ball Valve with
Check Valve Piped in Parallel
REFRIGERANTS
MAXIMUM RATED PRESSURE
MAXIMUM MEDIA
TEMPERATURE
FITTING MATERIAL
CERTIFICATIONS
MOUNTING ORIENTATION
FIGURE 1 - Valve Closed for Evaporator Service
Suction
PRESSURE
RELIEF
Note: The "A" side of the ball valve should always be on the same side as the coil.
Allows evaporator coil to be isolated without over pressurizing due to warm up. May also have needs in
loop piping and at the rack.
This symbol indicates the direction of pressure relief and direction of check valve feature. Flow
from left to right is check direction. Flow from right to left is pressure relief direction.
VS.
Class A1 refrigerants: HFC, HCFC, HFO (nontoxic and nonflammable),
and CO
.
2
1,305 psig (90 barg)
Continuous temperature range: -40 deg F to 248 deg F (-40 deg C to
120 deg C)
Installation temperature (15 minutes max.) limit: 300 deg F (149 deg C)
C19400 (K65) Copper
U.L. Recognized, File No. SA 5460, and
- Any
Evaporator
A
Coil
EBV-PR Ball Valve with
Integrated Pressure Relief
• Compact
• Eliminates check valve
• Reduces braze joints and leak potential
• Increases productivity
, RoHS
A
PRESSURE
RELIEF
Liquid

Publicité

loading

Sommaire des Matières pour Parker EBV-PR Serie

  • Page 1 Ball Valve with Integral Pressure Relief EBV(T)-PR Series INSTALLATION AND SERVICING INSTRUCTIONS SD-421 / 42021 Standard Ball Valve with EBV-PR Ball Valve with Check Valve Piped in Parallel Integrated Pressure Relief • Compact • Eliminates check valve • Reduces braze joints and leak potential •...
  • Page 2 Page 2 EN: IMPORTANT This valve has a pressure relief feature in one direction only. If installed incor- rectly, pressures may drastically increase causing rupture of valve, piping and/or other components exposed to such pressure. This could cause dam- age to equipment and cause injury or possible death to anyone in the area. FR: IMPORTANT Cette vanne possède une seule direction de décharge de pression.
  • Page 3 Page 3 FIGURE 3 90° 90° 90° CLOSED OPEN FERMÉ OUVRIR GESCHLOSSEN ÖFFNEN CHIUSO APERTO CERRADO ABIERTO PRESSURE RELIEF EN: OPERATION CAUTION: Pressure may be under seal caps, remove slowly. This valve con- NOTES tains mechanical stops. DO NOT USE EXCESSIVE FORCE AGAINST STOPS OR PERMANENT DAMAGE MAY OCCUR.
  • Page 4 Parker o dalle sue consociate o dai distributori autorizzati. Nella misura in cui Parker o le sue consociate o i distributori autorizzati forniscono opzioni di componenti o sistemi in base alle informazioni o alle specifiche indicate dall’utente, l’utente ha la responsabilità di verificare che tali informazioni e specifiche siano appropriate e sufficienti per tutte le applicazioni e gli usi ragionevolmente prevedibili dei componenti o dei sistemi.

Ce manuel est également adapté pour:

Ebvt-pr serie