Fitting electric components
Connect the electric control elements
S
(in accordance with the relevant operating
instructions).
Connect the motor to the controller (Z)
and the main power supply via an inter
mediately switched power amplifier.
Connect the reference point switch to
the controller power supply and the
controller (Z).
Connect the safety limit switch to the controller power supply and the
separately switched EMERGENCY STOP device (X) (è chapter Connecting
electric circuits").
Connect the hardware limit switch to the controller power supply and to the
controller (Z).
Installing circuitry
Note
If used in safety−relevant applications, additional measures are necessary.
In Europe, for example, the standards in the EC machinery directive must be
observed.
Without additional measures in accordance with statutory minimum
requirements, the product is not suitable for use in safety−related sections of
control systems.