DGE− −ZR−RF
If you are using inductive limit switches:
Avoid external influence caused by magnetic or ferritic parts in the vicinity of
S
the reference point switches and limit switches.
With use of inductive proximity switches SIE−...:
Fig. 22
aF = sensor lug
aG = sensor support
aH = proximity sensor
With small sizes, hammer head screws
(accessories) can be used for fastening
the sensor support in the groove.
These use the recess in the cover as a
guide channel.
A 90° turn will bring the hammer head
screw into its holding position.
Festo DGE− −ZR−RF 0906d English
aH
aG
aF
Fig. 23
Fig. 24