86
AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
If malfunctions occur
General data
Dimensions
Weight
Operating temperature range
Storage temperature range
Protection acc. to
EN 60529/IEC529
Compressed air quality
Workingpressure
Nominal flow
Mounting orientation
9.2
Maintenance
The bus coupler is maintenance-free.
O
Comply with the maintenance intervals and specifications
for the entire system.
9.3
Waste disposal
Dispose of the device in accordance with local regulations.
10 If malfunctions occur
In case of malfunction, refer to "Test and diagnosis" on page 75
for troubleshooting. Refer to "Replacement" on page 82 for
information on how to replace a faulty bus coupler.
11 Technical Data
Depends on configuration; see online catalogue.
Depends on configuration; see online catalogue.
0 C to +50 C, without condensation
–20 °C to +70 °C
When assembled: IP69K
To DIN ISO 8573-1, class 6, 4, 3 or lower
Solid pollutants: 5 µm
Dew point: 3 °C
Oil content: 1 mg/m
2,5 - 10 bar
950 - 1100 std. l/min, depending on valve type and subbase at 6 bar
pilot pressure, 1 bar
Any
3