Aventics DDL Mode D'emploi page 73

Bus coupler for series vs cl03/cl03-xl
Masquer les pouces Voir aussi pour DDL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 91
l
Table 12:
Function block diagram for switch S1
Supply lines
External,
wire 2, white
U
Q2
Via DDL
X71
External,
wire 1, brown
U
Q1
Table 13:
Example combinations for 32 valve solenoids
1)
Examples
Subbases used
Example 1
Subbases for double solenoid valves
Example 2
Subbases for double solenoid valves
Example 3
Subbases for double solenoid valves
1)
Other combinations may be selected in accordance with your requirements.
AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
2
1
2
1
2
1
2
2
S1.5
1
1
The following example combinations are available for the
assignment of the S1 switch and supply of assembled valves for
32 valve solenoids in Tab. 14.
Commissioning and Operation
Valve control supply
Actuated valves
double/single solenoid
S1.4
V13 – V16 / V25 – V32
S1.3
V9 – V12 / V17 – V24
S1.2
V5 – V8 / V9 – V16
S1.1
V1 – V4 / V1 – V8
Valve equipment
Double solenoid valves
Single solenoid valves
Single and double solenoid valves