7.5

To empty the spent mandrel container

Thespentmandrelcontainer(No.36)mustbeemptiedingoodtime;overfillingwillcause
the blind rivet setting tool to malfunction.
Unscrew the spent mandrel container (No. 36) by turning anticlockwise, collect spent
mandrels in suitable container.
Screw on spent mandrel container (No. 36).
8.

Maintenance and care

The complete grip mechanism must be maintained regularly.
8.1

To oil jaws

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (No. 2).
Dip the complete jaw mechanism up to the O-ring (No. 3) into an oil batch or wet jaws
(No. 5) with oil and allow to drip off.
Reassemble in reverse order.
8.2

To change jaws

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (No. 2).
Unscrew jaw housing (No. 4).
Remove jaws (No. 5).
Clean jaw housing (No. 4) and grease sliding surfaces.
Fit new jaws (No. 5) from the front (they are held by the grease).
Reassembleinreverseorder,ensuringthatallpartsarefixedtight.
8.3

To top up hydraulic oil

Follow correct sequence!
Wear safety goggles!
Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (No. 2).
Unscrew oil screw plug (No. 12) and seal (No. 13) using T20 Torx screwdriver.
Screwonsuppliedoilrefillreservoirwithcover.
20
Danger of oil escaping at high pressure.

Publicité