Télécharger Imprimer la page

Hella 8 008 614-001 Serie Instructions De Montage page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
The ultrasonic sensor can be used with headlamps with headlamp levelling device 6NM 007 282-231.
In individual cases use must be verified!
Page 4:
Mounting position
Depending on the vehicle type the
sensor must be mounted at a
suitable position underneath the
vehicle near one of the rear wheels
( ).
To achieve optimum illumination of
the road we recommend fitting the
additional optional front-axle sensor
11
on transporters, caravans etc..
Install the optional front-axle sensor
in the front area (front axle to the air
dam). ( )
Page 4:
Mounting steps
The following must be observed
when positioning the sensor:
1. Make sure there is sufficient
space for the sensor signal.
2. Mount at least 25 cm above the
ground.
3. Align the sensor at right angles
to the road surface.
Determine the mounting position on
the floor pan, mark the attachment
points and drill them at 3.5 mm
diameter (not in moving parts or the
fuel tank). Seal drilled metal parts
with antirust. Screw the mounting
bracket in place using 4.2 x 12 mm
self-tapping screws. Screw the
bracket and the mounting together.
4. Mounting should be in a place
where there is little potential
soiling (e.g. not in the wheel
housing behind the wheel).
5. Mounting should not be directly
near parts of the exhaust (effect
of heat).
Align the sensor vertically and
tighten.

Publicité

loading