9.5

First measures for troubleshooting

EHA18, EHA27, EHA45:
Disturbances / error
messages
Machine does not function
Water controller not functioning
Temperature display flashes
(999)
Water pump not running
EHA18E, EHA27E, EHA45E
Disturbances / error
messages
Machine does not function
Indicator light low water level
lights
Indicator light grid fault lights
Juice pump not running
No regulator function
Temperature display flashes
(999)
Water pump not running
Original operating manual Pasteurizer electrical
25.10.2021
Possible reason(s)
Phase missing
Phase swapped
Microfuse blown
Temperature sensor or cable
defective
Motor protection switch triggered
Water level in water tank too low
Possible reason(s)
EMERGENCY-OFF SWITCH
pressed
Water level in water tank too low
Phase missing
Phase swapped
Error level monitoring
Microfuse blown
Temperature sensor or cable
defective
Motor protection switch triggered
Troubleshooting
Remedy
Have an electrician
check this
Have an electrician
check this
Have an electrician
check this
Have an electrician
check this
Replenish water
Remedy
Unlock
EMERGENCY-OFF
switch
Replenish water
Have an electrician
check this
Check cable or blind
plug
Have an electrician
check this
Have an electrician
check this
Have an electrician
check this