8.4.2
Restarting after an emergency shut-down
-
Ensure all disturbances present have been cleared or damage to the machine has been
repaired.
-
Unlock the EMERGENCY-OFF switch (29).
-
Now start-up as you would after a scheduled shut-down.
8.5
Operation of EHA18, EHA27, EHA45
8.5.1
Step switch
Step switch for performance restriction (20)
The step switch restricts the performance of the heating unit as follows:
Step
0
1
2
3
8.5.2
Regulator settings
Temperature regulator water (41)
Increase set value
Decrease set value
8.5.3
Indicator lights
Indicator light heating (12)
If the indicator light Heating lights up, the water circuit is heated.
Indicator light water (14)
If the indicator light Water lights up, the water pump (21) is running and there is sufficient water in
the water tank (23).
Original operating manual Pasteurizer electrical
25.10.2021
EHA18
0 kW
9 kW
18 kW
18 kW
EHA27
0 kW
9 kW
18 kW
27 kW
Current water temperature
Set water temperature
Operation
EHA45
0 kW
15 kW
30 kW
45 kW
57 of 136