8.9
Decommissioning EHA18, EHA27, EHA45
For decommissioning, follow this procedure:
-
Switch off the main switch (11).
-
Disconnect power connection.
-
Disconnect the hose connections at the juice inlet (9) and the juice outlet (8).
-
Clean the machine.
-
The machine must be protected from frost. If this should not be possible, an anti-freeze must be
added to the water tank (6) (adhere to the anti-freeze manufacturer's statements). To ensure
that the anti-freeze can distribute itself in the entire water circuit, you must switch the machine
and the water pump on again.
-
Store the heating unit according to the storage conditions.
8.10
Decommissioning EHA18E, EHA27E, EHA45E
For decommissioning, follow this procedure:
-
Switch the selectors Juice pump (30) and Heating (34) to Off.
-
Switch off the main switch (19).
-
Disconnect power connection.
-
Disconnect the hose connections at the juice inlet (22) and the juice outlet (16).
-
Clean the machine.
-
Open the juice outflow tap (27) to empty the juice pipe of the heat exchanger.
-
The machine must be protected from frost. If this should not be possible, an anti-freeze must be
added to the water tank (23) (adhere to the anti-freeze manufacturer's statements). To ensure
that the anti-freeze can distribute itself in the entire water circuit, you must switch the machine
and the water pump (21) on again, using the selector (34).
-
Store the heating unit according to the storage conditions.
Original operating manual Pasteurizer electrical
25.10.2021
CAUTION
Risks of burns due to hot connector pieces!
Risk of scalding due to hot liquids!
CAUTION
Risks of burns due to hot connector pieces!
Risk of scalding due to hot liquids!
Operation
62 of 136
English