8.7
Cleaning of EHA18, EHA27, EHA45
Clean the machine using clear water with a normal cleaning agent.
Cleaning of the juice pipe of the heat exchanger spiral
Quick cleaning:
-
Switch off the machine using the main switch (11).
-
Unscrew the flow through regulation (7). Instead, connect a hose and put the open end into a
drain.
-
You can drain the juice pipe through the juice inflow (9).
-
Once the juice pipe is empty, push a sponge rubber ball into the juice inflow (9). Connect a hose
and open the water tap. The water pressure pushes the sponge rubber ball through the juice
pipe and cleans it from the inside.
-
Repeat this process 3 times.
Thorough cleaning:
-
Switch off the machine using the main switch (11).
-
You can drain the juice pipe through the juice inflow (9).
-
Fill a container with water and cleaning agent.
-
Connect this container via a pump to the juice inlet (9) and to the juice outlet (8).
-
Switch the machine on using the main switch (11).
-
Turn the step switch (13) to 0
-
Depending on the cleaning agent (according to the statement of the manufacturer) run the
circulation process for 20 to 30 min.
-
Following this process, the system must be flushed well with clean water.
Original operating manual Pasteurizer electrical
25.10.2021
ATTENTION
Do not clean the machine with a steam cleaner or pressure washer!
CAUTION
Risks of burns due to hot connector pieces!
Risk of scalding due to hot liquids!
Operation
60 of 136
English