8.6
Operation of EHA18E, EHA27E, EHA45E
8.6.1
Selector and step switch
Selector juice pump (30)
This selector directly controls the juice pump (26).
Manual:
Off:
Auto:
Selector heating (34)
This selector controls the water pump (21) and the heaters in the water tank (23).
W.P.:
Off:
W.P. + burner:
Step switch for performance restriction (33)
The step switch restricts the performance of the heating unit as follows:
Step
0
1
2
3
Original operating manual Pasteurizer electrical
25.10.2021
The juice pump is switched on.
The juice pump is switched off.
The juice pump is now controlled by the regulator and adjusts the speed
to the temperature of the juice.
The water pump is switched on.
The water pump is switched off.
The water pump is switched on, and the heaters are also switched on to
heat the water.
EHA18
0 kW
9 kW
18 kW
18 kW
EHA27
0 kW
9 kW
18 kW
27 kW
Operation
EHA45
0 kW
15 kW
30 kW
45 kW
58 of 136
English