8.8
Cleaning of EHA18E, EHA27E, EHA45E
Clean the machine using clear water with a normal cleaning agent.
Cleaning of the juice pipe of the heat exchanger spiral
Quick cleaning:
-
Switch off the machine using the main switch (19) and switch the selectors Juice pump (30) and
Heating (34) to Off.
-
Remove the temperature sensor Juice (17) and connect a hose instead.
-
Put the open end into a drain.
-
Open the juice outflow tap (27) to empty the juice pipe of the heat exchanger.
-
Once the juice pipe is empty, push a sponge rubber ball into the juice outflow tap (27). Connect
a water hose and open the water tap. The water pressure pushes the sponge rubber ball
through the juice pipe and cleans it from the inside.
-
Repeat this process 3 times.
Thorough cleaning:
-
Switch off the machine using the main switch (19) and switch the selectors Juice pump (31) and
Heating (34) to Off.
-
Open the juice outflow tap (27) to empty the juice pipe of the heat exchanger.
-
Once the juice pipe is empty, close the juice outflow tap (27) again.
-
Fill a container with water and cleaning agent.
-
Connect the container to the juice pump (26) via the juice inlet (22) and to the juice outlet (16).
-
Switch the machine on using the main switch (19).
-
Turn the step switch (33) to 0.
-
Turn the selector Juice pump (30) to Manual, to switch the juice pump (26) on.
-
Depending on the cleaning agent (according to the statement of the manufacturer) run the
circulation process for 20 to 30 min.
-
Following this process, the system must be flushed well with clean water.
Original operating manual Pasteurizer electrical
25.10.2021
ATTENTION
Do not clean the machine with a steam cleaner or pressure washer!
CAUTION
Risks of burns due to hot connector pieces!
Risk of scalding due to hot liquids!