Note:
After switching on, the TMP-150/TMP-250 will automatically detect whether DMX 512 data is received or not.
If the data is received, the control LED flashes. If there is no data received at the DMX-input, the control LED
lights up permanently.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of TMP-
150/TMP-250.
- the controller is switched off or defective.
- the cable or connector is defective or the signal wires are swap in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.

DMX-protocol

Control-channel 1 - Horizontal movement (Pan) (within 530°)
Push slider up in order to move the head horizontally (PAN).
Gradual head adjustment from one end of the slider to the other (0-255, 128-center).
The head can be stopped at any position you wish.
Control-channel 2 - Vertical movement (Tilt) (within 280°)
Push slider up in order to move the head vertically (TILT).
Gradual head adjustment from one end of the slider to the other (0-255, 128-center).
The head can be stopped at any position you wish.
Control-channel 3 - Pan-movement with 16 Bit-resolution
Control-channel 4 - Tilt-movement with 16 Bit-resolution
Control-channel 5 - Pan/Tilt-speed
Decimal Hexad. Percentage S/F
0 0
00 00
0% 0%
1 1
01 01
0% 0%
2 249
02 F9
1% 98%
250 255
FA FF
98% 100%
Control-channel 6 - Dimmer intensity
Decimal Hexad. Percentage S/F
0 255
00 FF
0% 100%

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
S Maximum speed (tracking mode)
S Maximum speed (vector mode)
F Decreasing speed
S Maximum speed
F Gradual adjustment of the dimmer intensity from 0 to 100 %