OPERATION
After you connected the spot to the mains, the EUROLITE TMP-150/TMP-250 Moving Multi Lens Spot starts
running. During the Reset, the motors are trimmed and the device is ready for use afterwards.
Display and function buttons
• Press the Mode Button and select from the functions F1 – F5.
F1 - No function
F2 - Pan Reverse
With this function you can reverse the Pan-movement.
• Press the Mode button and select „F2".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
• Press Enter to confirm.
F3 - Tilt Reverse
With this function you can reverse the Tilt-movement.
• Press the Mode button and select „F3".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
• Press Enter to confirm.
F4 - Demo operation
In the Stand Alone mode, the TMP-150/TMP-250 can be used without controller. TMP-150/TMP-250 from
the controller and call up the internal program (F4).
• Press the Mode button and select „F4".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
• Press Enter to confirm.
F5 - Reset
With this function you can reset the device via the Control Board.
• Press the Mode button and select „F5".
• Press the Up button to select "y" if you wish to enable this function or press the Down button to select "n"
if you don't.
• Press Enter to confirm.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
Addressing
The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the TMP-150/TMP-250 will respond to the controller.
If you set, for example, the address to channel 7, the TMP-150/TMP-250 will use the channel 7 to 12 for
control.
Please, be sure that you don't have any overlapping channels in order to control each TMP-150/TMP-250
correctly and independently from any other fixture on the DMX-chain.
If several TMP-150/TMP-250 are addressed similarly, they will work synchronically.
Press the Up/Down-buttons for setting the desired starting address.
Controlling:
After having addressed all TMP-150/TMP-250, you may now start operating these via your lighting controller.
27/57
00021435.DOC, Version 1.1