THE INSTALLATION SPACE

Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24" (60.96 cm)
Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24" (60.96 cm) installation depth shown.
The top case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
• Water line can enter the opening through the floor or
back wall. The water line should be 1/4" O.D. copper
tubing or QuickConnect
line and water connection location, long enough to
extend to the front of the unit. Installation of an easily
accessible shut-off valve in the water line is required.
kit between the cold water

DIMENSIONS AND CLEARANCES

35"
Case Width
*83-1/2"
at
Rear
Depth Including Handles:
27-5/8" Stainless Steel Models
28-5/8" Professional Models
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings
between 90° and 130°.
130° Door Swing
115° Door Swing
Allow 25" (63.5 cm) minimum clearance for a full 130°
door swing. Allow 15" (38.0 cm) for pan removal.
For a 90° door swing, allow 4" (10.16 cm) minimum
clearance to a wall for framed and stainless steel
models. Allow 5" (12.7 cm) minimum clearance for
professional models. If the 90° doorstop position is
used, pan access is maintained but pan removal is
restricted.
See illustration on page 43 to determine door swing
interaction with adjacent cabinets or countertops.
41
25-3/4" Stainless Steel Models
Case Depth
* Shipping height. The
product can be adjusted
*84" From
to fit into a cutout that
Floor to
is 84-1/2" (214.63 cm)
Top Frame
max. height. Note that
the top case trim at the
front is 1/2" (1.27 cm)
higher and will overlap
upper cabinetry or soffit.
Use leveling legs and
36" Frame to
wheels for a maximum
Frame Width
1" (2.54 cm) height
adjustment.
90° Door Swing
*
"
4
(10.16 cm) stainless and
trimmed models.
"
5
(12.7 cm) Pro models.