Step 3 Install Side Panels - Monogram ZIFS360NHLH Instructions D'installation

Réfrigérateurs et congélateurs intégraux encastrés 36 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions - Standard Installation

STEP 3 INSTALL SIDE PANELS

Skip this step when not using side panels
If you are using 1/4" side panels, they should be insert-
ed into the case trim.
STEP 4 INSTALL ANTI-TIP BRACKET
WARNING
The unit is top-heavy and must be secured to prevent
the possibility of tipping forward.
AVERTISSEMENT
basculement
L'appareil ménager est beaucoup plus lourd
en haut et il faut le maintenir en place pour éviter la possibilité
de son basculement vers l'avant.
ADVERTENCIA
La unidad es pesada en su parte superior y se deberá asegu-
rar a fin de evitar posibles caídas hacia adelante.
• The kit supplied with the unit contains 2 lag bolts and 4
toggles with bolts. The wall bracket will be attached to
the wall in 4 places.
• Measure the opening where the unit is to be installed.
Mark the center with a vertical line.
• Measure up 81-1/2" (207.01 cm) from the floor. Mark
this point on the wall.
• Using a level, draw a horizontal line on the wall at this
height.
31-49140-2
Tip Over Hazard.
Risque de
Riesgo de Caídas
Fasten the panels to the unit with stick-on hook and loop
fastener strips before setting unit in place.
• Locate at least 2 studs on the back wall. Mark these
points on the horizontal line.
• Place the bottom of the wall bracket with tabs on the
horizontal line. Align the center notch on the bracket
with the center line on the wall.
Two Additional
Hole Locations at
Ends of Brackets
• The anti-tip wall bracket has a series of holes. Select 2
holes that match with the located studs. Make sure the
holes selected are on the center of the studs. Mark the
wall at these points.
Line on Wall
• Mark an additional hole at each end of the bracket. If
one of the studs is closer to the end of the bracket, mark
an additional hole towards the center of the bracket.
• Drill 1/2" (1.27 cm) holes into the wall board at the loca-
tions marked for the toggles to be mounted (not the stud
markings).
• Drill 3/16" (0.47 cm) holes into wooden studs where
marked. If steel stud construction, drill 1/2" (1.27 cm)
holes into the studs where marked. You will use 2 tog-
gles with the metal studs.
15
Wall Bracket
Center
Line On Wall
Wall Studs
Center