Back Cleansing, Back Cleansing-Mild, and Front Cleansing
Symptom
Water shut-off valve is closed.
The strainer is clogged.
The water pressure is low. Water
pressure is set to the lowest set-
ting.
Seat sensor is not triggering.
Nozzle spray
does not dis-
charge.
The temperature of the water sup-
plied to the SpaLet seat is too high.
It takes longer
than usual for the
The water temperature is not set to
nozzle spray to
an appropriate temperature.
discharge.
The preparation
time before the
When purchasing a replacement model, the preparation time before the
nozzle spray dis-
nozzle spray discharges may be longer due to changes in product de-
charges may be
sign.
longer than mod-
This is a feature of the product and is not a malfunction.
els you have used
in the past.
Cause
Turn the open/close knob 180°
counterclockwise.
Clean the strainer.
Press the [ + ] side of the [Spray
Strength] button.
Sit on the SpaLet
This is not a malfunction. When the
water temperature exceeds 104°F
due to anti-freezing pipe heaters or
similar, the nozzle spray does not
discharge until hot water is removed
from the pipe. In this scenario, drain
the hot water from the pipes by
nozzle drain the SpaLet seat and
then try pressing the button for the
desired cleansing function. If this
phenomenon occurs repeatedly,
then review the usage of the anti-
freezing pipe heater.
This is not a malfunction. When
water temperature is low such as in
winter, it may take time to prepare
warm water before the nozzle spray
discharges.
Solution
®
seat.
Page
7
40
15
21
-
-
-
44 - EN