Protective Devices - SMA Sunny Tripower CORE1-US Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10 Technical Data
Output power at
+60°C (+140°F) at
minimum MPP voltage
Output power at
+60°C (+140°F) at
maximum MPP voltage
Power factor at rated
power
Range of the displace-
ment power factor (ad-
justable)
Output phases
Line conductor
Surge category in ac-
cordance with
UL 1741
* Depending on the configured country data set
Efficiency
Maximum efficiency,
η
max
CEC weighted effi-
ciency, η
CEC
Multifunction Relay
Maximum DC switching voltage
Maximum AC switching current
Maximum DC switching current
Minimum load
Minimum electrical endurance when the maxi-
mum switching voltage and maximum switching
current are complied with*
* Corresponds to 20 years at 12 switching operations per day

Protective Devices

DC reverse polarity protection
64
STP33-62-US-41-IA-xx-13
STP 33-US-41
> 27.6 kVA
> 33.3 kVA
1
0.0 overexcited to 0.0
underexcited
3
3-(N)-PE
IV
STP 33-US-41
98.2%
97.5%
SMA Solar Technology AG
STP 50-US-41
> 34 kVA
> 38.5 kVA
1
0.0 overexcited to 0.0
underexcited
3
3-(N)-PE
IV
STP 50-US-41
98.2%
97.5%
30 V
1.0 A
1.0 A
0.1 W
100000 switching cycles
Short-circuit diode
STP 62-US-41
> 40.8 kVA
40.2 kVA
1
0.0 overexcited to 0.0
underexcited
3
3-(N)-PE
IV
STP 62-US-41
98.2%
97.5%
Installation Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sunny tripower core1-us stp 33-us-41Sunny tripower core1-us stp 50-us-41Sunny tripower core1-us stp 62-us-41Sunny tripower core1-usStp 33-us-41Stp 50-us-41 ... Afficher tout

Table des Matières