3.2 Combustible Finish

3.2.1 Trim Installation
NOTE: It is not required to use the #KZK-054 discharge trim (#KZK-
054DT) if desired to run finishing material up to the finishing material
standoff. Finishing material must not block the opening and must be
run evenly along the plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
Drywall stops at nishing material stando s around KZK
discharge opening. The discharge trim covers these
edges completely.
Combustible
Material
Discharge Trim
¾
3
(95mm)
Figure 3.5, Drywall Finish
Up to 1" (25mm) thick combustible material up to the edge
of discharge trim. 1" (25mm) combustible material cannot go
closer to discharge opening.
1" (25mm) combustible material goes on top of any
required non-combustible material on the replace.
Combustible
Material up to
1" (25mm) thick
Discharge Trim
4
"
(111mm)
Figure 3.6, Combustible Finish Material up to 1" Thick
16 FACING AND FINISHING
"
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Non-combustible materials, such as tile or stone, up to the air discharge
opening. Minimum air discharge opening must be maintained the entire
length of the air discharge opening.
Discharge trim is optional for this installation.
Non-combustible
material up to
discharge opening
¼
2
"
(57mm)
Figure 3.7, Non-combustible Material Trim Finish
Komfort Zone Kit #KZK-054 R.5