Plenum Preparation - Kozy Heat Fireplaces KZK-054 Mode D'emploi

Masquer les pouces Voir aussi pour KZK-054:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.2 Plenum Preparation

The plenum included with this kit has (5) openings for (4) plenum
collars for installation for units #CLW-50 or #CLW-ST.
1.2.1 #CLW-50
1.
The center cover plate does not need to be removed. Install (4)
plenum collars to (4) openings.
1.2.2 #CLW-ST
For certain installations, you may need to remove the center cover
plate (Figure 1.3) and install a plenum collar in the center of plenum.
Install the cover plate in the corresponding left or right side that you
need space for to maintain clearances to the vent system or heat
transfer kits (HTK-EXT or HTK-INT).
1.
Remove the (4) screws securing the center cover plate, as show
below.
2.
Install the plenum collar to either the right or left side,
depending on your installation.
3.
Install cover plate to opening that is not used. Secure with (4)
screws.
Install 6" collar to left or right side,
depending on your installation.
Install cover plate over opening not used.
Figure 1.3, #KZK-054 Plenum Cover Plate
4 INTRODUCTION
Remove center cover plate
for certain installations.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Komfort Zone Kit #KZK-054 R.5

Publicité

Chapitres

Table des Matières
loading

Table des Matières