3.2 Combustible Finish

NOTE: If you desire to run finishing material up to edge of the discharge
opening,
see the drawing below.
air discharge grille and must be run evenly along the plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
3.2.1 Drywall Finish
IMPORTANT: Additional 1" (25mm) combustible trim on top of existing
materials is NOT allowed inside the side shelf enclosure (Section 2.3
Minimum Shelf Requirements on page 9).
1" (25mm) combustible material goes on top of any required non-
combustible material required on the fireplace as shown in Figures
3.1 and 3.2 on page 10.
Up to 1" (25mm) thick combustible material up to edge of the air discharge grille.
1" combustible material goes on top of any required non-combustible material required on replace.
7
"
(200mm)
Figure 3.3, Drywall Finish and Combustible Material up to 1" Thick around Discharge Grille
Komfort Zone Kit #KZK-158A R.2
Finishing material must not block the
Drywall stops at edge of air discharge opening.
Air grille discharge will overlap edges of drywall.
(381mm)
7"
(178mm)
1" combustible material cannot go closer to discharge opening.
15
"
(403mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
15"
Combustible
Material up to
1" (25mm) thick
Discharge Grille
7
"
(200mm)
NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE
FACING AND FINISHING 11